KAFI SMART

TITRA SMART Titrator

TITRA SMART is provided with two-point auto calibration and standardisation (zero offset). The instrument is capable of displaying pH and mV of the sample, with temperature compensation. TITRA SMART can accept a variety of electrodes to cater to various applications in different fields. The liquid path comprises Teflon tubing, Teflon lined valve and gas tight burette with Teflon plunger head. It creates chemically inert system for any sensitive analysis. The instrument is supplied with high speed vortex stirrer with digital speed indication. This specially designed stirrer provides excellent homogenous mixing of samples. An optional magnetic stirrer is also available.

Standard Features

  • 1
  • User interactive software in dialogue mode for ease of operation with protection against invalid entries.
  • 2
  • Vortex stirrer for vigorous and homogenous stirring with specially designed glass propeller for total chemical inertness.
  • 3
  • Quick interchangeable imported burette assemblies with intelligent recognition for its volume size. Burette factor for dispensing corrections is available for true end point calculations.
  • 4
  • Composite Differential Electrode Amplifier unit for Potentiometric and Voltametric / KF Titrations, having connectivity to various Electrodes.
  • 5
  • Temperature Sensor with 4-line measurement technique ensures correct temperature indication.
  • 6
  • Three standardised modes of titration, namely incremental, equilibrium and cut- off by pH mode to perform almost all types of titration. By selecting titration method, instrument prints the type of appropriate electrode.
  • 7
  • During titration, the measured variable i.e. electrode potential (mV) or the pH value is shown on the display together with dispensed volume and number of End Points (EP) detected.
  • 8
  • User selectable End Point (EP) evaluation up to 9 EP during the run, and calculation by first, last, largest, all or selected EP with display of results and printout.
  • 9
  • Alphanumeric entry of Sample Name, Titrant Name, Identification Number, Date with type of Electrode used for authentication. Daily Auto Incremented Run number and Factory entered CUSTOMER NAME and Instrument Sr. No. on report printouts make the system foolproof and GLP compliant.
  • 10
  • Facility to use as a dispenser for fixed volume dosing or dilution allows to perform manual titration with user defined dose and mV indication.
  • 11
  • Predispense facility with selectable dose and time for quick titrant addition without disturbing the titration trend.
  • 12
  • Automatic evaluation of molarity for standardisation of titrant, storage of 20 molarities and their retrieval for calculation.
  • 13
  • Compliant to ASTM D664, D2896 & D4739 for TAN and TBN analysis for oil samples.
  • 14
  • Titrant temperature factor for volume correction.
  • 15
  • Result recalculation facility to obtain printout in different units such as molarity, factor, % assay (wt), % volume (ml), ppm, mg/l, mg/g, ml/g, g/l, meq/l, mol/kg, TAN & TBN for oil samples.
  • 16
  • Reprocessing of threshold and recalculation of EP without performing the new run.
  • 17
  • Statistic function with Run Selectivity for finding Mean, S.D., R.S.D., and C.V. of last 10 repeat run results could be viewed or printed.
  • 18
  • User Programmed selectivity for report format, complying with GLP requirements: a) Report giving parameter and result. b) Data table giving mV, pH, mV, mV/ml, 2nd derivative and volume (μl). c) Graphics report giving mV v/s μl titration curve. d) Graphics report 1st derivative graph v/s μl titration curve. e) Graphical report of 2 derivative curve. f) Report of method parameters for 50 methods. g) Condensed report of titration parameters and results. h) Auto evaluation report for multi EP samples - EP1, EP2-EP1 etc. available. The reports can be obtained even after resetting/power off/power fail conditions.
  • 19
  • Real Time Clock (RTC) for time display and report printout with run time indication.
  • 20
  • Balance interface to directly transfer the sample weight.
  • 21
  • TITRA can be conver ted to perform Karl Fischer titrations by simply changing burette assembly. All the specifications of LABINDIA Karl Fischer Titrator are applicable.
  • 22
  • Online graphic display to analyse Sample Reaction Trend.
  • 23
  • Display Syringe filled status on screen.
  • 24
  • Complete 21 CFR Compliant with 6 Password levels with various privilege options, audit trail and e-signature.
  • 25
  • Unlimited user password storage.
  • 26
  • Password expiry policy.